Version: 2012.10.01 (A)  (6 Nov 2012) |
| |
Fixes |
| |
|
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
Important Notes:
This System ROM flash does require a bootblock flash using AFUDOS. There is NO online flash capability with this ROM release.
Firmware Dependencies:
None
Problems Fixed:
Resolved an issue where the server will not boot when replacing a hard disk drive with a different drive model number. The new BIOS allows a selection for a newly added hard drive with a different model number to be placed at the bottom of the hard disk drive boot sequence.
Resolved an issue where the server was unable to boot from PXE NIC using the IPMITOOL chassis bootdev pxe command.
Resolved an issue where the ESC+Q and ESC+( keys would not properly switch between serial console and LO100 CLP.
Resolved an issue where the Mellanox 10Gb PCIe Single Port NIC would intermittently fail to train to the correct speed.
Resolved an issue where the NC362i NIC would periodically initialize at x! PCIe bandwidth on a reboot.
Resolved an issue where the web (HTTP) connection to LO100 management is disabled each time the user enters the ROM Setup Utility and executes a Save and Exit.
Known Issues:
None
|
|
| |
| » |
Version: 2012.05.01 (A)  (13 Jun 2012) |
| |
Fixes |
| |
|
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Important Notes: This System ROM flash does require a bootblock flash using AFUDOS. There is NO online flash capability with this ROM release.Firmware Dependencies: NoneProblems Fixed: Resolved an issue where processor sensor thresholds were incorrect and were causing alerts in VMware vCenter. The SDR tables were updated to the correct threshold values.Resolved an issue where NIC 2 could be lost after clearing CMOS. Resolved an issue where the BIOS Serial Console Redirection would not operate properly with a HP SmartArray P410 controller using all the current latest Smart Array FW 5.x releases (5.06 - 5.14) with Protected Memory Mode support. Known Issues: None
|
|
| |
| |
Version: 2012.02.01 (A)  (10 Feb 2012) |
| |
Fixes |
| |
|
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
Important Notes: This System ROM flash does require a bootblock flash using AFUDOS. There is NO online flash capability with this ROM release.Firmware Dependencies: NoneProblems Fixed: Resolved an issue where the HP NC362i Integrated Dual Port Gigabit Server Adapter intermittently initializes to a lower PCI-express bandwidth than intended resulting in potentially degraded performance.Resolved an issue where the Windows Device Manager reports a conflict with I/O resources for the TPM Module. Known Issues: None
|
|
| |
| » |
Version: 2011.09.01 (B)  (4 Nov 2011) |
| |
Fixes |
| |
|
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
Important Notes:
SP55180 ver. 2011.09.01 (B) provides the same system ROM image as SP54779 ver. 2011.09.01 (A). Support is added in ver. 2011.09.01 (B) to perform the System ROMPaq Flash without user interface. The user does not need to flash the system ROM with ver. 2011.09.01 (B) if the system has previously been flashed with ver. 2011.09.01 (A).
This SoftPaq version will execute the "afudos" utility to upgrade the system bios due to a bootblock change.
Firmware Dependencies:
None
Problems Fixed:
Resolved an issue that may result in any of the following conditions: operating system stops responding, unexpected system reset, Blue Screen when using a Microsoft Windows operating system, kernel panic when using a Linux operating system, or Purple Screen when using VMware ESX. A message may be displayed by the operating system or logged in the Event Log when this issue occurs indicating an "Uncorrectable Machine Check Exception." However, there are instances where the system resets before the operating system displays an error message and instances where the Event Log contains no log entry when this issue occurs. This issue does not occur if the Intel C-State tech is configured to "disabled" or the C State package limit setting is set to "C1" or "C3". The system is susceptible to this issue in the default Intel C-State tech and C State package limit setting configurations.
Known Issues:
None
|
|
| |
| » |
Version: 2011.06.15 (A)  (26 Jul 2011) |
| |
Enhancements |
| |
|
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
Important Notes: This firmware provides support for the ProLiant DL180, DL160se and DL288 G6 servers. This release of the firmware is the minimum version required to support the ProLiant DL288 G6 server. It contains no new fixes or enhancements for the DL180 or DL160se G6 servers. Firmware Dependencies: NoneEnhancements/New Features: This is the initial version of the firmwware for the ProLiant DL288 G6.Known Issues: None
|
|
| |
| » |
Version: 2011.05.05 (A)  (20 May 2011) |
| |
Fixes |
| |
|
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
Important Notes: NoneFirmware Dependencies: NoneProblems Fixed: Resolved an issue where the system will intermittently display less than the total amount of memory installed after a cold reboot.Resolved an issue where the Power Supply Redundancy mode will change to Balanced Mode after a power supply failure and will not change back to High Efficiency mode after replacing the failed power supply. Resolved an issue where two installed P410 Smart Array controllers will both report as installed in PCI-e Slot2. Resolved an issue where the system will hang on the first boot after using CONREP to set the BIOS Serial Console. Known Issues: None
|
|
| |
| » |
Version: 2011.01.24 (B)  (2 Feb 2011) |
| |
Fixes |
| |
|
Upgrade Requirement: Critical - HP requires users update to this version immediately.
Important Notes: This release is only critical if your current system ROM is dated 01/06/11. There is an issue with the 01/06/11 ROM which could cause some systems to hang during POST with a "627-Invalid or Unknown SKU/Chassis ID" error message.
Firmware Dependencies: None
Problems Fixed:
Resolved an issue where some DL180G6/DL160seG6 systems could fail by hanging with "627-Invalid or Unknown SKU/Chassis ID" POST error message with 01/06/11 BIOS.
Resolved an issue where the SmartStart Scripting Toolkit command RBSURESET was not working.
Resolved an issue where on the first boot after clearing CMOS, system will attempt to PXE boot from NIC Port1.
Resolved an issue where ORCA screen information was not being displayed properly when using Console Redirection.
Resolved an issue where 'QPI_Frequency', 'Memory_Frequency', 'Advanced_Memory_Protection', and 'Restore_on_AC_Power_Loss' options could not be modified by CONREP.
Resolved an issue where hard disk drives could not be detected when 'SATA#1 Controller' mode was set to 'RAID' and 'BIOS Serial Console' was set as 'Enabled'.
Known Issues: None
|
|
| |
| » |
Version: 2010.08.17 (A)  (14 Sep 2010) |
| |
Fixes |
| |
|
Upgrade Requirement: Recommended - HP recommends users update to this version at their earliest convenience.
Important Notes: NoneFirmware Dependencies: NoneProblems Fixed: For servers using Intel Xeon processor 5600 series, resolve an issue where an uncorrectable memory error may occur. If this error occurs, the system may generate a blue screen if using Microsoft Windows operating systems, generate a panic if using a Linux operating system, or become unresponsive. In addition, the System Health LED may be illuminated amber and the System Event Log may have an event indicating the uncorrectable memory error. These errors do not indicate a problem with the memory DIMMs or the server system board. This issue is not unique to HP ProLiant servers and is resolved by a new revision of Intel's microcode for Intel Xeon processor 5600 series that is implemented in this version of the System ROM. Intel Xeon processor 5500 series processors are not affected by this issue. Note: After completing the flash upgrade process for this revision of the System ROM, the server should be power cycled.Updated the Redundant Fan SDR table to prevent possible false sensor warnings as fan speeds are reduced at boot-up time. Known Issues: None
|
|
| |
| » |
Version: 2010.07.23 (A)  (4 Aug 2010) |
| |
Fixes |
| |
|
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Important Notes: NoneFirmware Dependencies: NoneProblems Fixed: Resolved an issue where the Power Efficiency mode was being set to "Custom" any time CONREP was used to set system configuration options. Known Issues: None
|
|
| |
Enhancements |
| |
|
Added a feature to detect memory initialization errors at boot-up time. Added a BIOS Setup menu option for selecting the number of active processor cores as a related item for Power Efficiency Mode. Added a staggered spin-up time for installed hard drives during system power-on for better power management.
|
|
| |
| » |
Version: 2010.05.19 (A)  (8 Jun 2010) |
| |
Fixes |
| |
|
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Important Notes: NoneFirmware Dependencies: NoneProblems Fixed: Resolved an issue where system running RHEL5 with a Xen kernel intermittently does not shut down properly.Known Issues: None
|
|
| |
Enhancements |
| |
|
Added staggered spin-up of installed hard drives at system power-on for more better power management.
|
|
| |
| » |
Version: 2010.03.31 (A)  (5 May 2010) |
| |
Fixes |
| |
|
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Important Notes: NoneFirmware Dependencies: NoneProblems Fixed: Resolved an issue where the second of two installed 400W redundant power supplies is not displayed properly in the BIOS Setup Menu.Resolved an issue where certain Micron memory DIMMs might not be detected properly or might show false overtemp warnings during POST. Resolved an issue where uncorrectable memory errors might display the logical DIMM location rather than the correct physical slot number during POST and/or in the System Event Log. Moved VT-d menu option in the BIOS setup menu to align with other virtualization-related settings. Known Issues: None
|
|
| |
Enhancements |
| |
|
Updated to new ProLiant splash screen. Implemented power efficiency improvements for 95W processor configurations.
|
|
| |
| » |
Version: 2010.02.04 (B)  (9 Feb 2010) |
| |
Fixes |
| |
|
Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Fixes:
Important Notes: None
Firmware Dependencies: None
Problems Fixed: Resolved an issue where the system would not boot to CD or DVD with two LSI SAS3081E-R HBAs installed.
Resolved an issue where uncorrectable memory errors recorded in the System Event Log did not correctly indicate the failed DIMM location via the Lights-Out 100 System Event Log interface.
Resolved an issue where disabling the embedded NIC via the BIOS setup menu does not actually disable it.
Known Issues: None
|
|
| |
Enhancements |
| |
|
Enhancements: Added support in the BIOS setup menu for enabling/disabling VT-d (virtualization technology for directed I/O).
|
|
| |
| » |
Version: 2009.12.03 (A)  (7 Jan 2010) |
| |
Fixes |
| |
|
Upgrade Requirement: OptionalUsers should update to this firmware revision if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this revision. Important Notes: NoneFirmware Dependencies: NoneProblems Fixed: Resolved an issue where the One Button Disaster Recovery feature would not work with SAS devices.Resolved an issue where the One Button Disaster Recovery feature would not work with USB devices under Windows Server 2003. Resolved an issue where setting the PCI Express mode to Gen2 in the BIOS Setup Menu did not set the PCI Express mode to Gen2. Resolved an issue where the system could hang when both an nVidia FX3800 graphics card and an Infiniband card were installed, with Node Interleaving enabled. Known Issues: None
|
|
| |
Enhancements |
| |
|
Added a "QPI Optimization" option in the BIOS Setup Menu. It is recommended that this setting be left in the default state for most configurations.
|
|
| |
| » |
Version: 2009.11.06 (A)  (9 Dec 2009) |
| |
Fixes |
| |
|
Upgrade Requirement: OptionalUsers should update to this firmware revision if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this revision. Important Notes: NoneFirmware Dependencies: NoneProblems Fixed: Resolved an issue where SmartArray controllers upgraded to FW versions 2.50 or later may sometimes not be detected at POST.Resolved an issue where redundant fans were not properly displayed in the BIOS Setup Menu. Known Issues: None
|
|
| |
Enhancements |
| |
|
Added an option in the BIOS Setup Menu to select edge or level triggered interrupts for the serial port.
|
|
| |
| » |
Version: 2009.10.15 (A)  (28 Oct 2009) |
| |
Fixes |
| |
|
Upgrade Requirement: OptionalUsers should update to this firmware revision if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this revision. Important Notes: NoneFirmware Dependencies: NoneProblems Fixed: Resolved an issue where systems with the NC522SFP Dual Port 10GbE network card installed may experience grey screen hangs at POST.Known Issues: None
|
|
| |
Enhancements |
| |
|
Added an option in the BIOS Setup Menu to allow for selecting memory interleaving in one node. Disabled turbo mode when the user selects Efficiency mode in the BIOS Setup Menu.
|
|
| |
| » |
Version: 2009.09.03 (A)  (30 Sep 2009) |
| |
Fixes |
| |
|
Upgrade Requirement: OptionalUsers should update to this firmware revision if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this revision. Important Notes: NoneFirmware Dependencies: NoneProblems Fixed: Lengthened the delay time of the system summary screen during POST to allow users time to view information.Resolved an issue where the system can hang during POST in configurations where the OS boot drive is attached to a P212 Smart Array controller. Resolved an issue where the BIOS Setup Menu displayed an incorrect name for the HP SC40Ge Host Bus Adapter. Resolved an issue where multiple erroneous events with ID 57 are created in the System Event Log (SEL) under a Microsoft Windows OS. Known Issue: None
|
|
| |
Enhancements |
| |
|
Added support for 16Gb DIMMs.
|
|
| |
| » |
Version: 2009.07.28 (A)  (17 Aug 2009) |
| |
Fixes |
| |
|
Resolved an issue where a system with a HP SmartArray P410 controller combined with a HP StorageWorks FC1142/FC1242/FC2242 PCI Express Host Bus Adapter fails to boot, displaying a "PCE uncorrectable error".
Resolved an issue where the system will generate multiple "Bus Correctable Error" events in the System Event Log (SEL) when configured with HP StorageWorks PCIe Fibre Channel Host Bus Adapter.
Resolved an issue where a system with a HP SmartArray P410 controller and a HP NC382T PCI Express Dual Port Server Adapter, in certain slot configurations, may not boot to the hard drive under SLES 10 SP2.
Resolved an issue where, a single fan failure in a configuration with fan redundancy, causes the health LED to incorrectly blink red instead of amber.
Resolved an issue where pressing "Ctrl+B" at POST to configure the HP NC522SFP Dual Port 10GbE Server Adapter will cause a system hang.
|
|
| |
| » |
Version: 2009.07.05 (B)  (15 Jul 2009) |
| |
Fixes |
| |
|
Resolved issue with HP NC364T PCI Express Quad Port Gigabit Server Adapter not being properly recognized in certain slots. Resolved issue with hang with HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter when exiting option ROM configuration via F4.
|
|
| |
Enhancements |
| |
|
Added Drive Write Cache support for AHCI mode.
|
|
| |