HP Integrity rx4640 Server - Specifications
 System Specifications
| Processor and Memory
|
Supported processors
(Min=1, Max=4) |
1.6 GHz Intel Itanium 2 processor with floating point coprocessor:
- Cache on-chip level 1: 32 KB
- Cache on-chip level 1: 256 KB
- Cache on-chip level 1: 9 MB or 6 MB
1.5 GHz Intel Itanium 2 processor with floating point coprocessor:
- Cache on-chip level 1: 32 KB
- Cache on-chip level 1: 256 KB
- Cache on-chip level 1: 3 MB or 4 MB
HP mx2 dual-processor module (contains two 1.1 GHz Itanium 2 processors) with floating point coprocessor:
- Cache on-chip level 1: 32 KB
- Cache on-chip level 1: 256 KB
- Cache on-chip level 1: 4 MB
|
| System memory |
Minimum memory
: 1 GB
Maximum memory capacity
: 128 GB |
Standard Interfaces Specifications
| Networking and I/O
|
| Maximum network interface cards |
1000Base-SX
: 6
1000Base-TX
: 6
10/100Base-TX
: 6
Dual-port X.25
: 6
ATM
: 6 |
| Maximum mass storage host bus adapters |
Ultra320 or Ultra160 SCSI-LVD
: 6
Dual-port Ultra160 SCSI-LVD
: 6
Smart Array 6402
Ultra320 SCSI RAID
: 3 total
2-Gb single-port fibre
channel
: 6 |
| Standard integrated I/O |
Ultra320 or Ultra160 SCSI-LVD
: 2 channels
10/100/1000Base-T (RJ-45
connector)
: 2 ports
RS 232 serial ports
: 3
10/100Base-T management port (RJ-45
connector)
: Yes
USB and VGA
: Yes |
| I/O buses and slots |
Available PCI-X slots
: 6
- Two 133 MHz, 64 bit slots on dedicated PCI X buses
- Four 66 MHz, 64 bit slots distributed on 2 PCI X buses; 2 slots per bus
|
Mass Storage Specifications
| Supported Hard Drives
|
| Internal disks |
Maximum disks
: 2
Maximum disk capacity
: 292 GB |
Physical Specifications
| Site Preparation
|
| Depth |
690 mm (27.2 in) |
| Width |
482 mm (19 in) |
| Rack height |
4U (173mm) |
| Weight (maximum) |
45 kg (100 lb) |
Electrical Specifications
| Electrical Characteristics
|
| AC input power |
200-240V 50-60 Hz |
| Hotswap power supplies |
1 included, 2nd for N+1 |
| Redundant AC power
inputs |
1 included, 2nd for N+1 |
| Maximum input current |
8 A at 240 VAC (shared across inputs) |
| Typical maximum power
dissipation |
1065 Watts |
| Conservative maximum
power dissipation |
1368 Watts |
| Power factor at full load |
0.95 or higher |
| Typical heat dissipation
(BTUs/hour) |
3600 |
| Maximum heat
dissipation (BTUs/hour) |
5500 |
Environmental Specifications
| Environmental Characteristics
|
| Acoustics (operator/bystander)
at 25o
C (77o
F) |
< 7.2 Bels LwA |
| Operating temperature
(up to 1524 m/5000 ft)a
|
5o
to 35o
C (41o
to 95o
F) |
| Non-operating
temperature |
-40o
to 70o
C (-40o
to 158o
F) |
| Maximum rate of
temperature change |
20o
per hour |
| Operating relative
humidity |
15% to 80% RH non-condensing |
| Non-operating relative
humidity |
5% to 90% non-condensing |
| Operating altitude above
sea level |
3000 m (10000 ft) maximum |
| Non-operating altitude
above sea level |
4500 m (15000 ft) maximum |
| a. Max operating temperature range up to 1524 m (5000 ft). For higher altitudes de-rate the max temperature by 2o
C/1000 ft
above 1524 m (5000 ft). |
Safety Certifications
| Regulatory Compliance
|
| RMN |
RSVLA-0201 |
| Electromagnetic interference |
Complies with FCC Rules and Regulations, Part 15 as a Class A digital device.
Manufacturer's Declaration to EN55022 Level A, VCCI Registered, Class A, Korea RLL |
| Safety |
UL Listed, CSA Certified, UL GS Mark compliant with EN 60950 and EN 41003 |
Link to Product Overview Information
|
|