HP Integrity rx5670-4 Server - Overview
 Product description
|
The HP Integrity rx5670 Server, powered by 1-4 Intel Itanium 2 processors, improves price/performance in enterprise HP-UX, Linux or Windows environments. The HP Integrity rx5670 empowers technical computing users to do more simulations, perform more in-depth analysis, run complex models faster, and render high-quality images with optimized performance. |
Product Features
| Features
|
Specifications
|
| Performance/ scalability/ flexibility |
- 1 to 4 Intel Itanium 2 processors
clock frequency
-
Clock frequency: 1.3 GHz or 1.5 GHz
- System bus bandwidth: 6.4 GB/s
|
| Cache (on-chip) |
- Level 1 cache: 32 KB
-
Level 2 cache: 256 KB
-
Level 3 cache: 6MB @ 1.5 GHz, 3MB @ 1.3 GHz
|
| Net weight |
Maximum configuration: 72.6 kg (160 lbs) |
| Physical dimensions |
- Height: 311 mm (12.25 in) / 7U EIA
-
Width: 482 mm (19 in)
-
Depth: 774 mm (30.5 in)
|
| Main memory |
- Bus bandwidth: 12.8 GB/s
-
RAM Type: PC2100 ECC registered DDR266A SDRAM
-
Capacity: 96 GB Max
-
Memory slots: 48 DIMM slots on two 24 slot extenders
|
| Internal storage devices |
- Internal hard disk drive bays: 4
-
Ultra320 SCSI: 36 GB, 73 GB, and 146 GB drives available
-
Removable media: 1 open bay for DVD-ROM or DDS
|
| Maximum internal storage |
584 GB (4x146 GB) |
| Expansion slots |
- PCI-X slots available: 9 (3 x 133 MHz, 6 x 66 MHz)
-
PCI slots available: 1 (33 MHz)
-
I/O bandwidth: 4 GB/s
|
| Core I/O and management processor interconnect |
- 10/100/1000BT LAN
-
Ultra160 SCSI
-
10/100BT management LAN
-
3 x RS-232 serial ports
-
VGA (optional)
-
2 x USB (optional)
|
| Power supply |
Max output: 930 W per supply |
| Power requirements |
- Input current: 100V 10A - 200V 5A (per line)
-
Line frequency: 50-60 Hz
-
Maximum power input: 2089 W
|
| Altitude |
- Operating: 3048 m (10,000 ft) maximum
- Non-operating: 4572 m (15,000 ft) maximum
|
| Temperature |
- Operating: +5o
to +35o
C (+41o
to +95o
F)
-
Non-operating: -40o
to +70o
C (-40o
to +158o
F)
|
| Humidity |
Operating: 15% to 80% RH non-condensing |
| Regulatory |
- Regulatory model number: RSVL-0105-A
|
Software Overview
| Support Operating System
|
| HP UX 11i version 2, Windows Advanced Server, and Linux |
| Management Software
|
- HP Ignite-UX for installation and deployment of the operating system
-
HP Software Distributor-UX for software and patch management
-
HP Servicecontrol Suite for HP-UX
- HP TopTools for Windows and Linux
-
Management processor for comprehensive remote management of HP-UX, Windows, and Linux
-
Process Resource Manager for HP-UX workload management
|
Links to Product Specification and Warranty Information
|
|