HP Integrity rx2620 Server - Specifications
 System Specifications
| Processor and Memory
|
| Supported processors |
1.3-GHz Intel Itanium 2 processor
- 3 MB
cache
- Floating point coprocessor
1.6-GHz Itanium 2 processor
- 3 MB cache
- Floating point coprocessor
|
| System memory |
Minimum memory
Maximum memory capacity
|
Component Specifications
| Storage, I/O and Adapters
|
| Internal disks |
Maximum disk mechanisms
Maximum disk capacity
|
| Standard integrated I/O |
Ultra320 SCSI-LVD
10/100/1000Base-T (RJ-45 connector)
RS-232 serial ports
USB
10/100Base-T management port
(RJ-45 connector)
VGA graphics
|
| I/O buses and slots |
Total PCI-X/PCI slots
All four slots are 133-MHz, 64-bit slots on dedicated PCI-X buses |
| Maximum mass storage host bus adapters
|
Ultra160 SCSI–LVD
Dual-port Ultra160 SCSI–LVD
Smart Array Ultra160 SCSI RAID
- 3 (only 1 for internal drives)
2-Gb single-port fibre channel
|
| Maximum network interface cards |
1000Base-SX
1000Base-TX
10/100Base-TX
Dual-port X.25
4-port 10/100Base-TX
PCI-X Dual Port GigE-TX
PCI-X Dual Port GigE-SX
|
Physical Specifications
| Rack and Pedestal Dimensions
|
| Rack form factor |
- Height: 86 mm (3.4 in) / 2U EIA
-
Width: 482 mm (19 in)
-
Depth: 680 mm (26.8 in)
|
| Pedestal form factor |
- Height: 495 mm (19.5 in)
- Width: 297 mm (11.7 in)
-
Depth: 672 mm (26.5 in)
|
| Net Weight |
Maximum configuration: 25 kg (56 lbs) |
Electrical Specifications
| Electrical Characteristics
|
| AC input power |
100-240 V 50/60 Hz |
| Hotswap power supplies |
1 included, 2nd for N+1 |
| Redundant AC power inputs |
1 included, 2nd for N+1 |
| Current requirements at 230 V |
4 A (shared across inputs) |
| Typical maximum power dissipation |
600 Watts |
| Theoretical maximum power dissipation |
1,350 Watts |
| kW rating for UPS loading |
1.3 |
| Typical heat dissipation (BTUs/hour) |
1,945 |
| Maximum heat dissipation (BTUs/hour) |
4,375 |
Environmental Specifications
| Environmental characteristics
|
| Acoustics (operator/bystander) at 25o
C (77o
F) |
< 6.8 Bels LwA |
| Operating temperature
(up to 1524 m/5000 ft)*
|
5o
to 35o
C (41o
to 95o
F) |
| Non-operating temperature |
-40o
to 70o
C (5o
to 35o
F) |
| Maximum rate of temperature change |
10o
C/hour |
| Operating relative humidity |
15% to 80% RH non-condensing |
| Non-operating relative humidity |
8% to 85% non-condensing |
| Operating altitude above sea level |
3,000 m (10,000 ft) maximum |
| Non-operating altitude above sea level |
4,600 m (15,000 ft) maximum |
Safety Certifications
| Regulatory Compliance
|
| RMN |
RSVLA-0403 |
| Electromagnetic interference |
Complies with FCC Rules and Regulations, Part 15 as a Class A digital device. Manufacturer's Declaration to EN55022 Level A, VCCI Registered,
Class A, Korea RLL, CCC, BMSI Taiwan |
| Safety |
CSA NRTL Certified, EN 60950-1 |
Link to Product Overview Information
|
|